遼寧力士樂伺服驅(qū)動器維修:機械設(shè)備在使用過程出現(xiàn)點故障是正常的,尤其是像機械設(shè)備用的時間太長了,出現(xiàn)故障的概率更多,今天要講的是力士樂伺服驅(qū)動器產(chǎn)品,當力士樂伺服工作中出現(xiàn)故障,要怎么處理維修呢,接下來一起看看相關(guān)內(nèi)容。
力士樂伺服驅(qū)動器維修:
F218故障代碼:Heatsink Overtemperature Shutdown散熱器超溫停機
故障描述:Description:
The temperature of the DKC heatsink will be monitored. If the
temperature of the heatsink is too high, the drive will power down in order
to protect against damage.
將監(jiān)控DKC散熱器的溫度。如果散熱器溫度過高,驅(qū)動器將依次斷電以防止損壞。
原因:Cause:
1. Ambient temperature is too high. The specified operational data is valid up to an ambient temperature of 45°C.
環(huán)境溫度過高。指定的操作數(shù)據(jù)在環(huán)境溫度以下有效45°C。
2. The DKC's heatsink is dirty.
DKC的散熱器臟了。
3. Air flow is prevented by other assembly parts or a control cabinet panel assembly.其他組件部件或控制柜面板組件阻止空氣流動。
4. Heatsink blower may be defective
散熱器鼓風機可能有故障
解決方法:Remedy:
1. Reduce the ambient temperature; for example, through cooling
of the control cabinet。降低環(huán)境溫度;例如,通過冷卻控制柜的
2. Remove any obstruction or dirt from the heatsink.
清除散熱器上的任何障礙物或污垢。
3. Install the device vertically and clear a large enough area for
proper heatsink ventilation.
垂直安裝設(shè)備,并清理足夠大的區(qū)域,以確保散熱器通風良好。
4. Exchange drive.交換驅(qū)動器。
力士樂驅(qū)動器維修常見故障:無顯示維修、缺相維修、不能啟動維修,過流維修、過壓維修、欠壓維修、過熱維修、過載維修、接地維修、參數(shù)錯誤維修、有顯示無輸出維修、報警維修。電源跳閘,黃燈不亮,炸模塊,無輸出,輸出電壓低,輸出點無輸出,紅色燈亮,啟動無反應(yīng),不能啟動維修、開關(guān)電源損壞維修、模塊損壞維修、接地故障維修、不能調(diào)速維修、限流運行維修、數(shù)碼管不亮等。
轉(zhuǎn)載請注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動器維修,伺服電機維修
本文鏈接:http://www.51yrjj.com/fuwu/Services_Show11918.htm
伺服驅(qū)動器維修 伺服電機維修 觸摸屏維修 變頻器維修
電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.51yrjj.com
【 我們確保修好測試好給客戶!!!!】
下一篇:沒有了