力士樂高性能伺服驅(qū)動器維修:力士樂伺服驅(qū)動器是用來控制伺服電機的一種控制器,其作用類似于變頻器作用于普通交流馬達,伺服驅(qū)動器的故障與維修代碼有哪些,相應(yīng)故障排除技法有哪些,博士力士樂伺服驅(qū)動器維修專業(yè)公司上海仰光電子能夠速查伺服驅(qū)動器故障,快修伺服驅(qū)動器,排除伺服驅(qū)動器故障提供了有力的支持。
力士樂伺服驅(qū)動器維修案例:故障解析:
F644故障:Negative Travel Limit Switch Detected檢測到負行程限位開關(guān)
The negative travel limit switch has been actuated. The axis has been stopped with the error reaction "set velocity command value to zero". Bit 2 of P-0-0090, Travel limit parameter has been set to "Exceeding the travel limit is considered as an error", or a drive control command has been started while the axis limit value is exceeded (e.g. drive-controlled homing).負行程限位開關(guān)已啟動。軸已停止,錯誤反應(yīng)為“將速度命令值設(shè)置為零”。P-0-0090的第2位,行程限制參數(shù)已設(shè)置為“超過行程限制視為錯誤”,或在超過軸限制值時啟動驅(qū)動控制命令(例如驅(qū)動控制回零)。
Cause:原因:
The negative travel limit switch has been actuated.負行程限位開關(guān)已啟動。
Remedial action:解決措施:
1. Reset the error重置錯誤
2. Activate the power supply啟動電源
3. Move the axis into the permissible working range將軸移動到允許的工作范圍內(nèi)
Note: The drive will not accept any command values that lead further away from the permissible range. Specifying such a command will again result in this error.
注意:驅(qū)動器將不接受任何遠離允許范圍的命令值。指定這樣的命令將再次導致此錯誤。
轉(zhuǎn)載請注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動器維修,伺服電機維修
本文鏈接:http://www.51yrjj.com/fuwu/Services_Show12078.htm
伺服驅(qū)動器維修 伺服電機維修 觸摸屏維修 變頻器維修
電話:021-50157782
手機:13817011982 微信同號
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.51yrjj.com
【 我們確保修好測試好給客戶!!!!】
下一篇:常州INVY英威騰CHE100-011G-2變頻器OC報警故障維修