哪里有力士樂驅(qū)動(dòng)器維修:本公司專業(yè)維修博世力士樂Bosch-Rexroth全系列伺服驅(qū)動(dòng)器,常見維修故障E825過電壓、F277過電流、F873電源驅(qū)動(dòng)板故障、F267、F873、F868、F860、F878;VMZKS、F8070、+24V error、F8069、±15Verror;過載、缺相、BS紅燈亮、H1數(shù)碼管不亮、無報(bào)警無動(dòng)作不輸出、無顯示、電機(jī)抖動(dòng)、F30/61#/60#/20#、內(nèi)部冒煙/放炮等均可快速修復(fù)。
力士樂kdv系列伺服驅(qū)動(dòng)器維修:
F630 Negative Travel Limit Value is Exceeded
超過負(fù)行程極限值
The drive has been provided with a command value that leads to an axis
position outside the negative travel range. The axis has been stopped and
the error reaction "set velocity command value to zero" issued. Bit 2 of P-
0-0090, Travel limit parameter has been set to "Exceeding the travel
limit is an error", or a drive control command has been started while the
axis limit value is exceeded (e.g. drive-controlled homing).
驅(qū)動(dòng)器已提供一個(gè)指向軸的命令值位置超出負(fù)行程范圍。軸已停止,并且發(fā)出錯(cuò)誤反應(yīng)“將速度命令值設(shè)置為零”。P的第2位-0-0090,行程限制參數(shù)已設(shè)置為“超出行程
限制是一個(gè)錯(cuò)誤”,或者在超過了軸極限值(例如,驅(qū)動(dòng)控制復(fù)位)。
Cause:原因:
S-0-0050, Negative position limit value is exceeded.
S-0-0050,超過負(fù)位置限值。
Remedial action:補(bǔ)救措施:
1. Check S-0-0050, Negative position limit value
2. Check the controller software limits
3. Activate the axis after the error reaction
1.檢查S-0-0050,負(fù)位置限值
2.檢查控制器軟件限制
3.錯(cuò)誤反應(yīng)后激活軸
Procedure:程序:
• Clear the error
• Activate power if it has been de-activated
• Move the axis to the permissible working range
•清除錯(cuò)誤
•如果電源已停用,則激活電源
•將軸移動(dòng)到允許的工作范圍
友情提示:請(qǐng)勿自行拆卸檢查或交給非專業(yè)人士,以免越修越壞,造成不必要的經(jīng)濟(jì)損失!早一天聯(lián)系,少一天損失!上海仰光電子科技有限公司 因?yàn)閷Wⅲ詫I(yè)!
轉(zhuǎn)載請(qǐng)注明出處:上海仰光電子科技專業(yè)伺服驅(qū)動(dòng)器維修,伺服電機(jī)維修
本文鏈接:http://www.51yrjj.com/fuwu/Services_Show13996.htm
伺服驅(qū)動(dòng)器維修 伺服電機(jī)維修 觸摸屏維修 變頻器維修
電話:021-50157782
手機(jī):13817011982 微信同號(hào)
郵箱:shygdzi@163.com
聯(lián)系人:張工
網(wǎng)址:http://www.51yrjj.com
【 我們確保修好測(cè)試好給客戶!!!!】
下一篇:韶關(guān)西門子工控機(jī)IPC3000開機(jī)時(shí)打不開,出現(xiàn)一串英文字母故障哪里修