力士樂dds伺服驅動器維修說明:
Description:
Before starting an automatic control loop setting, both travel range limits,
i.e., upper and lower, must be defined.
在開始自動控制回路設置之前,即,上部和下部,必須定義。
When starting command P-0-0162, D9 automatic control loop setting the number values are automatically checked for validity. It is checked if the traversing path is large enough and if sensible values have been entered。
當啟動指令P-00162時,D9自動控制回路設置數值會自動檢查其有效性。
檢查遍歷路徑是否足夠大,以及是否輸入了合理的值
Possible fault causes:可能的故障原因:
• P-0-0167, upper traversing range smaller than P-0-0166, lower traversing range
P-0-0167,上部橫向范圍小于P-0-0166,下部橫向范圍
• Maximum traversing path (= upper - lower limits) is less than 6 motor rotations and thus too small to start the automatic control loop setting.
最大橫向路徑(=上限-下限)小于6個電機旋轉,因此太小,無法啟動自動控制回路設置。
Remedy:解決措施:
• clear command error by ending the command
通過結束命令來清除命令錯誤
• a) input new limits whereby:upper > lower limits
a) 輸入新的限制,其中:上限>下限
b) redefine limits to define a larger traversing range
b) 重新定義極限以定義更大的遍歷范圍
• restart command with sensible traversing range
具有合理遍歷范圍的重新啟動命令