HCS04.2E-W0590驅動器修理:
F218 Heatsink Overtemperature Shutdown散熱器過熱停機
Description:說明:
The temperature of the DKC heatsink will be monitored.將監測DKC散熱器的溫度。
If the temperature of the heatsink is too high, the drive will power down in order to protect against damage.
如果散熱器溫度過高,驅動器將斷電以防止損壞。
Cause:原因:
1. Ambient temperature is too high.
環境溫度過高。
The specified operational data is valid up to an ambient temperature of 45°C.指定的操作數據在環境溫度不超過45°C時有效。
2. The DKC's heatsink is dirty.
DKC的散熱器臟了。
3. Air flow is prevented by other assembly parts or a control cabinet panel assembly.氣流由其他組件零件或控制柜面板組件阻止。
4. Heatsink blower may be defective
散熱器鼓風機可能存在故障
Remedy:
1. Reduce the ambient temperature; for example, through cooling
of the control cabinet
降低環境溫度;例如,通過冷卻控制柜的
2. Remove any obstruction or dirt from the heatsink.
清除散熱器上的任何障礙物或污垢。
3. Install the device vertically and clear a large enough area for
proper heatsink ventilation.
垂直安裝設備,并清理足夠大的區域適當的散熱器通風。
4. Exchange drive.
更換驅動器
英格瑪特伺服維修:
HCS03.1E-W0070-A-05-NNNV
HCS03.1E-W0070-A-05-NNBV
HCS03.1E-W0100-A-05-NNNV
HCS03.1E-W0150-A-05-NNNV
HCS03.1E-W0150-A-05-NNBV
HCS03.1E-W0210-A-05-NNNV
HCS03.1E-W0210-A-05-NNBV
HCS03.1E-W03.50-A-05-NNNV
HCS03.1E-W0150-A-05-NNBN
轉載請注明出處:上海仰光電子科技專業伺服驅動器維修,伺服電機維修